Sundance Spas uses Electronic Temperature Sensors and High Limit Sensors to protect the Hot Tub user and the Spa from incorrect Water Temperature or Overheating.
Sort By:
1 2
6540-228, Sundance Spas O-ring in Teflon
List Price: $10.66
Our Price: $3.85

6540-228, Sundance Spas O-ring
4 Position Sensor Harness 6660-053
4 Position Sensor Harness 6660-053
MSRP $12.99
Sale Price $7.95

6660-053, Sensor Harness, 4 position.
The temp sensor and the High Limit sensor are installed into this harness. The 2 sensors are sold separately.
For 850E/Portofino, 780/Sweetwater, and 701/724 Temperature Sensors
Used On:
1. 2012+ 680 Peyton
2. 2011+Select Series 2006+ 780/680 Series
3. 2005 780,850E Series,Portofino, and Sweetwater.
4. 2003-2005 Del Sol Systems
5. 1998-2007 Solo
6. 1998-2007 701,724 Systems.
7. Replaces 6600-070, 6600-071 6600-104.
8. Used on All: Bahia, Burlington, Caprio, Cayman, Camden, Certa, Chelsee, Denali, Dover, Hamilton, Hartford, Hawthorne, Metro, Palermo, Solo, Tacoma.
9. Used on these Circuit Boards: 6600-286, 6600-287, 6600-288, 6600-289 and older versions of the circuit boards: 6600-082, 6600-084, 6600-086, 6600-087, 6600-088, 6600-089
These sensors are interchangeable with the 6600-167 except for the end connector which could be wire nutted on.
The Temp Sensors are located in the filter compartment on the side. They are unscrewed from the inside of the tub and the wire is fed through the tub into the equipment compartment. Follow the wire to the PC Board. To feed the new sensor, we usually drain the tub below the hole and pull the old sensor out a couple of feet into the tub, cutting the old sensor head off, we tie on the new sensor (connector end) to the old wire and pull the wire through into the equipment compartment.
The connectors on the Temp Sensor are attached to a pc board connector that is located on the PC Board (usually at the top). There are other wires connected to this plug: Jumper interlock wire,Flow Switch, High Limit and Temp sensor. Remove the pin connector from the board .
6560-410, Sundance Spas Temp Fitting
6560-410 Temp Sensor Fitting.
List Price: $28.91
Our Price: $14.85

6560-410, Sundance Spas Temp Fitting. For old style "bullet" sensor. For all 601 - 724 Systems
6000-093 Sundance Spas, High Limit Disc
6000-093 Sundance Spas, High Limit Disc
List Price: $22.74
Our Price: $15.92

6000-093, Sundance Spas, High Limit Disc
Used on Sundance Spas Heaters: 6500-301 Bypass Heater (1999-1/14/2000) and Smart Heater (2000-present)
6560-423 Sundance Spas Temperature Sensor
6560-423 Sundance Spas Temperature Sensor. For Balboa Systems Only!
List Price: $40.46
Our Price: $21.00

6560-423, Sensor with White Plug Connectors.
Do not use this sensor on 700 or 800 systems or newer 600, 600S systems.
FOR BALBOA SYSTEMS ONLY! Resistance cannot be checked. Make sure of your system, this does not work on any other systems than what is listed. This temp sensor is NONRETURNABLE except for warranty
Use 6540-228 Oring (sold separately)
 

6600-129, Sundance Hi-Limit Sensor
6600-068, Sundance Hi-Limit Sensor
List Price: $36.00
Our Price: $25.84

6600-068 High Limit Sensor. Cable length 7"5"
  • The difference between the 6600-140, 6600-144 (same sensor both 24") and 6600-068 (length is 90 inches approx.) is the length of the cable.
  • Used on:
  • 2012+ 680 Peyton
  • 2011- Select Series
  • 2008+ 680 Denali, Tacoma
  • 2008+ 780 Dover
  • 2008-2012 680 Burlington model equipped with or without Circ Pump.
    2007+ 680 Hartford and Hawthorne Models equipped with or without a circ pump.
    2007+ Hamilton, Chelsee, Certa and Camden.
  • 2006 Caprio, Metro, Solo, and 680 Models
    2006 Palermo, Bahia and Cayman.
  • 2005 850 E Models
    2005 780, Sweetwater and Del Sol Models (With Curled finger connectors)
  • 1998-2004 Portofino Models
  • 1989-1991 701-724 systems (with curled finger connections)
    Replaces 6600-140,
    6600-129 (came without sensor harness, same sensor same length). Can replace the 6600-144, 6600-140 (cable length 2'8" will just have extra cable)

6600-144, Sundance Hi-Limit Sensor
6600-144, Sundance Hi-Limit Sensor for All 2005+ 780, Sweetwater, and Del Sol Models
List Price: $38.58
Our Price: $27.01

6600-144 High Limit Sensor
The difference between the 6600-140, 6600-144  (same sensor both 24") and 6600-129 (old number 6600-068, length is 90 inches approx.) is the length of the cable.
Used on:
2012+ 680 Peyton
2011- Select Series
2008+ 680 Denali, Tacoma
2008+ 780 Dover
2008-2012 680 Burlington model equipped with or without Circ Pump.
2007+ 680 Hartford and Hawthorne Models equipped with or without a circ pump.
2007+ Hamilton, Chelsee, Certa and Camden.
2006  Caprio, Metro, Solo, and 680 Models
2006 Palermo, Bahia and Cayman.
2005 850 E Models
2005 780, Sweetwater and Del Sol Models (With Curled finger connectors)
1998-2004 Portofino Models
1989-1991 701-724 systems (with curled finger connections)
Replaces 6600-140
6600-168 Sundance Spas Hi-Limit Sensor
6600-168 Sundance Spas Hi-Limit Sensor, For All 650,850 and 880 Systems, 1995+(Spas with Bypass Heaters) Smart Heater
List Price: $38.58
Our Price: $27.01

6600-168, Sundance Hi-Limit Sensor
Models used on: All 650,850 and 880 Systems, 1995+ Spas with Bypass Heaters (Stainless) and Smart Heater (Gray Plastic)
6600-166, Sundance Spas Temperature Sensor
6600-166 Sundance Spas, Sweetwater Spas Temperature Sensor w/curled finger connectors.
List Price: $54.91
Our Price: $28.88

6600-166, Temperature Sensor with Curled Finger Connectors.
(Use with 6540-228 Oring (sold separately, see below in related products.)
Used On:
1. 2012+ 680 Peyton
2. 2011+Select Series2006+ 780/680 Series
3. 2005 780,850E Series,Portofino, and Sweetwater.
4. 2003-2005 Del Sol Systems
5. 1998+ Solo
6.  Used on 701,724 Systems. 
7. Replaces 6600-070, 6600-071
 6600-104.
8. Used on All: Bahia, Burlington, Caprio, Cayman, Camden, Certa, Chelsee, Denali, Dover, Hamilton, Hartford, Hawthorne, Metro, Palermo, Solo, Tacoma.
9. Used on these Circuit Boards: 6600-286, 6600-287, 6600-288, 6600-289 and older versions of the circuit boards: 6600-082, 6600-084, 6600-086, 6600-087, 6600-088, 6600-089
6600-167, Sundance Spas Temperature Sensor
6600-167, Sundance Spas Temperature Sensor
List Price: $54.91
Our Price: $30.98

6600-167, Temperature Sensor with Box End Connectors.
Use with 6540-228 Oring (sold separately)
Used on these spas.
1. 2012+ Aspen
2. 2005+ 880 Systems
3. 1997-2005 850 Systems. 400,600,600-S,750, 800 and 850 Systems.
4. 1992 Suncoast, 4/96-4/98 Suntub SV/DV Systems. 
5. 1997+ 850 Systems
6. Replaces #6600-138 and 6600-105(not shown). 
7. Interchangeable with 6600-182 sensor (stainless steel) with box end connectors.
For Inground Spas (spas with remote equipment with no skirt) see 6600-169
   
 